TROUBLE
SHOOTING
GUIDE
Sootmaster Manual - PN 376566 Rev G - Printed in USA 03/09/05
PAGE 8
TOOLS, ACCESSORIES
AND OPTIONAL FILTERS
Dacron Filter Bag
1) Install a disposable paper filter bag on
to the vacuum inlet fitting.
2) Install the Dacron Filter Bag in around
the outside of the cloth filter assembly so
the elastic top sits on the filter's gasket.
3) Position the filter assembly on top of
the tank, replace the motor head on tank
and close the clamps.
2 Ply Intermediate Filter
1) Install a disposable paper filter bag on
to the vacuum inlet fitting.
2) Place the 2 Ply Intermediate Filter in
position on top of tank,
3) Folding the filter over the outside of
tank. Overlap it approximately one inch.
4) Place the cloth filter assembly on the
the tank, being carefully not to move 2 ply
filter. The filter's gasket must sit evenly on
the tank rim so that an air tight seal will
be obtained.
5) Replace motor head assembly on top
of the filter assembly, and resnap
holdown clamps.
Address:
777 South Street, P. O. Box 2310
Newburgh NY 12500-0606
Tel:
(800) 835-7812 W (845) 565-8850
Fax:
(800) 752-6883 W (845) 565-9392
E-Mail
Optional Filters
The use of the Intermediate or Dacron Bag Filter gives added protection to the motor head and life to the cloth filter.
________________________________
Ref Description Part
No No
________________________________
1 6 Ft Flexible Metal Hose 304409
2 27" Crevice Tool 304352
3 Blower Nozzle 304425
4 10 Ft Rubber Lined Canvas Hose 344923
5 Upholstery Tool 386413
6 14" Hose Cage
(For 14" Tanks) 313408
Optional Filters
7A 14"-2 Ply Intermediate Filter 347515
7B 16"-2 Ply Intermediate Filter 363375
8A 14" Dacron Filter Bag 300861
8B 16" Dacron Filter Bag 300888
________________________________
PROBLEM: Loss of Vacuum.
CAUSE: SOLUTION:
1) Full paper filter bag. 1) Replace paper filter bag.
2) Dry filter clogged or gasket worn 2) Clean cloth filter or replace gasket.
3) Clogged hose or wand. 3) Remove obstruction.
4) Canister rim dented. 4) Replace canister.
5) Loose or broken fan. 5) Contact manufacturer or service center.
6) Motor not working. 6) Contact manufacturer or service center.
PROBLEM: Motor is not running.
CAUSE: SOLUTION:
1) Faulty ON/OFF switch. 1) Contact manufacturer or service center.
2) Power cord defective. 2) Contact manufacturer or service center.
3) Loose connection or wiring. 3) Contact manufacturer or service center.
4) Motor defective. 4) Contact manufacturer or service center.
5) Blown fuse or tripped circuit breaker. 5) Replace fuse or reset circuit breaker.
PROBLEM: Dust blowing from vacuum when running.
CAUSE: SOLUTION:
1) Paper filter bag full or torn. 1) Replace filter bag.
2) Paper filter bag not installed 2) Reinstall or replace paper filter bag
properly.
properly or off inlet tube.